Image-based Analysis of Uniaxial Ring Test

A tensile test divider icon

Dr. Kurniawan and his team at Eindhoven University of Technology develops an image-based approach to the common uniaxial ring test for mechanical characterization of soft materials and biological tissues.

CellScale hexagon shapes

A Uniaxial ring test is conducted by stretching a ring-shaped specimen in 2 opposite directions using pins or hooks. It is a common test for a variety of materials, from industrial elastomers to soft biological tissues. However, systematic errors can occur in the simultaneous compression, bending and stretching during the test that is geometry-dependent.

Dr Kurniawan and his team from Eindhoven University of Technology work to resolve that by introducing a simple image-based analysis approach, accurately estimating the sample mechanical properties for a wide range of ring geometries. The samples were tested in an uniaxial displacement controlled experiment on the CellScale BioTester, with modified rakes: the pins point upward rather than downward, and the rakes were painted black to facilitate the automated analysis of the BioTester images. As proof of concept, they tested their approach on rat vascular grafts and discover a clear temporal change in the mechanical properties of these grafts after implantation.

Read the full journal article here: https://doi.org/10.1039/C8SM02343C

To read about an engineered meniscus with zone-specific biochemical composition, click here.

CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

BioTester

TAGS

Biomechanical testing methods, BioTester, Elastomer testing, Image-based analysis, Ring test, soft tissue mechanics, Uniaxial testing, Vascular graft mechanics

POST DETAILS
CATEGORY

Research Highlights

INSTRUMENT USED
BioTester
RESEARCH APPLICATIONS
Scaffold Mechanical TestingVascular Tissue Engineering & Mechanics
TESTING METHODS
Digital Image Correlation (DIC)Tensile Testing

Related Posts:

Filter by Category:
Filter by Instrument
Filter by Testing Method:
Filter by Research Application:
CellScale UniVert mechanical testing system performing a mouse femur three-point bending test, with a magnified illustration of cortical bone and osteocyte canaliculi.

November 5, 2026

Mouse Femur Three-Point Bending Reveals Reduced Bone Strength Despite Preserved Bone Mass

Illustration of an ascending aortic aneurysm at the 5 cm diameter threshold alongside a biaxial mechanical testing setup for measuring aortic tissue stiffness.

October 28, 2026

Aortic Aneurysm Biomechanics: What Changes at the 5 cm Threshold?

Bioprinted neural tissue models showing soft and stiff GelMA hydrogel stiffness conditions of approximately 2 kPa and 4 kPa.

October 21, 2026

How GelMA Hydrogel Stiffness Affects Bioprinted Neural Tissue Models

Devil ray swimming at depth with an inset showing spherical micro-indentation of tessellated cartilage using a MicroTester-style tungsten microbeam.

October 7, 2026

Cartilage Mechanical Testing Reveals Differences Across Deep-Diving Devil Ray Species

Aortic tissue sample undergoing biaxial testing with four BioRakes, showing circumferential and longitudinal loading and a DIC strain map.

October 1, 2026

Aortic Biaxial Testing Reveals Subtle Changes After Intermittent Hypobaric Hypoxia

Ultrasound probe measuring tumor stiffness in a laboratory mouse, with a color-coded elastography map showing stiffness variation within the tumor.

September 25, 2026

Tumor Stiffness Measurement: Validating In Vivo Poroelastography with Mechanical Testing

Contact Sales

Product of Interest:
CellScale hexagon shapes