PEER-REVIEWED PUBLICATION

2026

Screening ADA-GEL based hydrogel formulations and bioprinting conditions for myoblast encapsulation and alignment

A tensile test divider icon

Lu HH, Steinert C, Böhringer D, et al.

Bioprinting

University of Erlangen-Nuremberg, Fraunhofer Institute for Manufacturing Engineering and Automation, University of Hohenheim

RESEARCH SUMMARY
This study systematically screened alginate dialdehyde-gelatin (ADA-GEL) hydrogel formulations and extrusion-bioprinting conditions to identify combinations suitable for skeletal muscle biofabrication with C2C12 mouse myoblasts. Six ADA-GEL formulations varying in polymer concentration, ADA-to-gelatin ratio, and gelatin preparation temperature were first compared for printability, rheological behavior, swelling, degradation, and cytocompatibility. Medium-concentration formulations containing 2.5% ADA and 5% gelatin provided the best balance of shape fidelity, manageable printing pressure, and cell compatibility, while low-concentration short-chain gelatin formulations lacked structural stability and high-concentration formulations required excessive printing pressure. The researchers then compared 37 °C- and 80 °C-prepared gelatin formulations, with and without silicate-based bioactive glass nanoparticles, and evaluated conical versus cylindrical printing nozzles. Mechanical testing showed that the 37 °C-prepared ADA-GEL hydrogels were generally stiffer than their 80 °C-prepared counterparts and that adding 0.1% nanoparticles had little effect on compressive modulus. All formulations softened substantially after immersion in culture medium but then maintained relatively stable effective modulus values through 14 days. Bioprinting experiments showed that conical nozzles generally required lower pressures and supported higher C2C12 viability than cylindrical nozzles. The 37_ADAGEL formulation printed through a conical nozzle produced the highest cell viability at days 3 and 7 and the greatest tendency for actin alignment along the printing direction, with an average angular deviation of approximately 13°. Incorporation of bioactive glass nanoparticles preserved printability and supported cell viability and alignment, with the 37_ADAGEL_NP formulation outperforming its 80 °C-prepared counterpart. Overall, the study identified 2.5% ADA-5% gelatin prepared at 37 °C and extruded through a conical nozzle as the most favorable system among the tested conditions for C2C12 skeletal-muscle bioprinting, while demonstrating how hydrogel formulation, mechanical properties, nozzle geometry, and printing pressure interact to influence printability and cellular response.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

MicroTester

A CellScale MicroTester LT was used to quantify the compressive mechanical properties of selected ADA-GEL and ADA-GEL/bioactive-glass nanoparticle hydrogels over a 14-day incubation period. Cylindrical hydrogel specimens measuring 5 mm in diameter and 2 mm in height were prepared from 37_ADAGEL, 80_ADAGEL, 37_ADAGEL_NP, and 80_ADAGEL_NP formulations. Samples were mechanically characterized before incubation and after 1, 3, 7, and 14 days in HBSS at 37 °C, with six specimens tested per condition. Depending on the required force range, the MicroTester LT was configured with 60 mm-long cantilever beams having diameters of 0.5588, 0.4064, or 0.3048 mm and a 6 × 6 mm compression plate. Effective compressive modulus was calculated from the 0-5% strain region. Initial testing showed that 37 °C-prepared hydrogels were stiffer than the corresponding 80 °C-prepared formulations; 37_ADAGEL had an initial effective modulus of approximately 3.2 ± 1.0 kPa, while 80_ADAGEL was approximately 1 kPa. After one day of immersion, all four formulations exhibited a substantial decrease in modulus because of hydrogel swelling and thermal softening under the physiologically relevant 37 °C aqueous testing conditions. From day 1 through day 14, effective moduli remained comparatively stable, indicating that water uptake and material degradation had reached a mechanical balance over this period. Addition of 0.1% silicate-based bioactive glass nanoparticles had little effect on effective modulus relative to the corresponding nanoparticle-free ADA-GEL formulations. The MicroTester measurements therefore provided a quantitative mechanical basis for comparing candidate bioinks and showed that gelatin preparation method had a greater effect on hydrogel stiffness than nanoparticle incorporation. These results were used alongside rheology, swelling, degradation, printability, and cell studies to select ADA-GEL formulations suitable for skeletal muscle bioprinting.
AUTHORS

Hsuan-Heng Lu, Clara Steinert, David Böhringer, Margitta Büchner, Dirk W. Schubert, Sahar Salehi, Aldo R. Boccaccini.

PUBLICATION DETAILS
JOURNAL

Bioprinting

YEAR

2026

INSTITUTIONS

University of Erlangen-Nuremberg, Fraunhofer Institute for Manufacturing Engineering and Automation, University of Hohenheim

COUNTRIES

Germany

INSTRUMENT USED

MicroTester

TESTING METHODS

Compression TestingHydrated and Temperature Controlled TestingMicro-Mechanical Testing

RESEARCH APPLICATIONS

3D Bioprinting & Bioink Materials TestingCell Laden HydrogelsHydrogel Mechanical TestingSkeletal Muscle & Volumetric Muscle Loss

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Cell-generated forces recapitulate geometry-defined deformation modes in auxetic and non-auxetic micro-architected scaffolds

Parlanis A, Farsari M, Ranella A

Cell Reports Physical Science

MicroTester

Compression TestingMicro-Mechanical Testing

Scaffold Mechanical TestingStem Cell Mechanobiology

2026

A Multi-Crosslinkable Methacrylated Alginate-GelMa Bioink for Drop-on-Demand Bioprinting

Bui T, Karakaya E, Faber J, et al.

Macromolecular Bioscience

MicroTester

Compression TestingHydrated and Temperature Controlled TestingMicro-Mechanical Testing

3D Bioprinting & Bioink Materials TestingCell Laden HydrogelsHydrogel Mechanical Testing

2026

The nonlinear mechanics of single electrospun polyurethane fibers under wet and dry conditions

Madariaga A, Lohr MJ, Beck JL, et al.

Soft Matter

MicroTester

Flexural and Bending TestingMicro-Mechanical TestingViscoelastic & Time-Dependent Testing

Material Fatigue and DurabilityPolymers and Elastomers Testing

2026

Contact Sales

Product of Interest:
CellScale hexagon shapes