Resolving differential vascular graft remodeling using longitudinal multiphoton tracking in a 3D culture platform

A tensile test divider icon

Maestas DR Jr, Murphy TR, Martinet KM, et al.

Materials Today Bio

University of Pittsburgh, McGowan Institute for Regenerative Medicine, University of South Carolina

RESEARCH SUMMARY
This study developed an organotypic 3D artery-graft culture platform designed to preserve the cylindrical geometry of tissue-engineered vascular graft interfaces while enabling non-destructive longitudinal monitoring of remodeling at substantially higher resolution than conventional implantation studies. Rat or mouse aortic explants were positioned adjacent to acellular tubular vascular grafts on PTFE-coated mandrels using 3D-printed holders, creating single-interface, interpositional double-interface, or aortic injury configurations. A compliance-matched trilayered electrospun TEVG composed of a PESBUU-50 luminal layer and PEUU-gelatin middle and outer layers served as the primary graft design. Before culture studies, tubular mechanical characterization was used to tune this graft’s passive circumferential compliance to the physiological response of native rat abdominal aorta. Longitudinal multiphoton imaging then tracked tissue-graft remodeling for up to eight weeks using second harmonic generation to visualize fibrillar collagen and endogenous two-photon excited fluorescence to monitor cell-associated signals. Newly deposited collagen appeared as short, thin fibers at early time points and progressively developed into longer and thicker fibrillar structures by weeks 6-8. Cellularization could also be followed longitudinally and was validated through nuclear labeling and immunostaining for vimentin and α-SMA. Importantly, the collagen architecture generated after eight weeks of ex vivo culture showed strong agreement in fiber length, width, straightness, and orientation with six-month rat interpositional graft explants using the same compliance-matched design, although both remodeled graft conditions differed substantially from healthy helical aortic collagen architecture. A second PESBUU-50 graft design also showed broadly similar scaffold-specific remodeling trajectories between culture and long-term implantation. The platform detected biologically induced remodeling differences following TGF-β1, TGF-β2, and TGF-β3 treatment, with each isoform producing distinct collagen microstructural and gene-expression responses. Overall, the study establishes a relatively accessible intermediate model for longitudinally screening vascular graft designs and remodeling trajectories before or alongside resource-intensive animal implantation studies.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

Custom CellScale Tubular Testing System

A custom CellScale tubular mechanical testing system, described in the publication as a ‘closed-end tubular biaxial mechanical loading device,’ was used to characterize the pressure-diameter compliance of native rat abdominal aortas and electrospun tissue-engineered vascular grafts and to tune the compliance-matched TEVG design used throughout the study. Before testing, aortas and TEVGs were washed with 37 °C DPBS and allowed to acclimate for 20 minutes. The CellScale sample bath was maintained at 37 °C and filled with DPBS for graft testing, while native aortas were tested in Krebs-Henseleit passive buffer to suppress vascular smooth muscle cell activity. Samples were cannulated to the tubular sample holders, secured with suture thread, and sealed against leakage with UV-curable adhesive. The system camera was calibrated to track specimen outer diameter while load and internal pressure were recorded. Samples were tested under taut axial stretch intended to reproduce implantation loading, generally corresponding to an axial stretch ratio of approximately 1.3-1.5 for rat aorta and further defined by an axial load of 0.10 ± 0.02 N. Nine loading cycles were used for preconditioning and the tenth cycle was retained for analysis. Circumferential compliance was calculated from the change in outer diameter between 70 and 120 mmHg normalized to the corresponding pressure interval. The CellScale measurements showed that the optimized trilayered compliance-matched TEVG achieved a circumferential compliance within the native rat aortic range, whereas a thickened-middle-layer hypocompliant TEVG produced a lower compliance. These measurements established the mechanical design criterion for the principal scaffold subsequently used in the longitudinal artery-graft remodeling platform and enabled direct comparison of ex vivo remodeling with companion long-term implantation studies using the same mechanically tuned TEVG.
AUTHORS

David R. Maestas Jr., Trin R. Murphy, Katarina M. Martinet, Tracey Moyston, Leon Xuanyu Min, Ali Behrangzade, Brock J. Pemberton, Jincy Joy, Sang-Ho Ye, George S. Hussey, Mohamad Azhar, William R. Wagner, Jonathan P. Vande Geest.

PUBLICATION DETAILS
JOURNAL

Materials Today Bio

YEAR

2026

INSTITUTIONS

University of Pittsburgh, McGowan Institute for Regenerative Medicine, University of South Carolina

COUNTRIES

United States

INSTRUMENT USED

Custom CellScale Tubular Testing System

TESTING METHODS

Biaxial TestingHydrated and Temperature Controlled TestingPressure Testing

RESEARCH APPLICATIONS

Polymers and Elastomers TestingScaffold Mechanical TestingVascular Tissue Engineering & Mechanics