PEER-REVIEWED PUBLICATION

2025

An Investigation of the Mechanism of Adjacent Segment Disease in a Porcine Spine Model

Chow N, Sinopoli SI, et al.

Clinical Biomechanics

Wilfrid Laurier University, McMaster University

RESEARCH SUMMARY
This study investigated how spinal fixation and injury affect the mechanical properties of adjacent intervertebral discs, using porcine and human cadaveric models. Fifty-two porcine cervical spines were divided into control, injured, immobilized, and injured+immobilized groups, subjected to cyclic axial compression (300–1200 N, 0.5 Hz, 2 hours). Annular tissue samples from the adjacent disc (C3/4) were tested for intralamellar and interlamellar mechanical properties. Immobilization significantly reduced toe-region and failure stresses of the intralamellar matrix (p < 0.03), particularly in the posterior annulus, while peel strength between lamellae was unchanged. Similar reductions in toe-region stress were observed in human lumbar discs. These findings reveal how immobilization weakens annular integrity, providing a mechanistic basis for adjacent segment disease following spinal fusion.

CELLSCALE INSTRUMENT USED

BioTesterUStretch

Single lamellae were mounted using five-prong tungsten BioRakes on a CellScale BioTester with collagen fibers oriented perpendicular to the rakes to isolate intralamellar matrix response. Samples were preconditioned (3×10% strain, 1%/s) and pulled to failure at 1%/s to determine stiffness, toe-region, and failure properties. Multilamellar annular samples were tested on a CellScale UStretch in a 180° peel configuration (0.5 mm/s) to assess interlamellar adhesion. Results showed immobilization reduced intralamellar failure stress from 0.53 ± 0.58 to 0.13 ± 0.06 MPa (p = 0.003), with minimal changes to interlamellar peel strength, demonstrating selective weakening of annular layers adjacent to fixation.
AUTHORS

Noah Chow, Sabrina I. Sinopoli, Mitchel C. Whittal, Drew A. Bednar, Diane E. Gregory.

PUBLICATION DETAILS
JOURNAL

Clinical Biomechanics

YEAR

2025

INSTITUTIONS

Wilfrid Laurier University, McMaster University

COUNTRIES

Canada

INSTRUMENT USED

BioTesterUStretch

TESTING METHODS

Hydrated and Temperature Controlled TestingMicro-Mechanical TestingPeel TestingTensile Testing

RESEARCH APPLICATIONS

Fibrosis & Tissue RemodelingIntervertebral Disc BiomechanicsMechanotransductionMusculoskeletal Tissue Engineering & Mechanics

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Postpartum biomechanical adaptations of the anterior abdominal wall in a rat model: Implications for diastasis rectus abdominis

Lax M, Morgan M, et al.

Clinical Biomechanics

BioTester

Tensile Testing

Musculoskeletal Tissue Engineering & MechanicsPelvic Floor and Gynecological Biomechanics

2026

Comparison of Mechanical Properties of Patient-Specific Direct 3D-Printed Aortic Valve for Simulation Trainings: A Comparative Study

Cheheili Sobbi S, Pavlykova-Chertovska A, et al.

Innovations

BioTester

Digital Image Correlation (DIC)Tensile Testing

Cardiac Tissue Engineering & MechanicsHeart Valve Tissue Engineering & MechanicsPolymers and Elastomers Testing

2026

A deep neural network surrogate for fast mechanical parameter identification using the ring tensile test

Utrera A, Navarrete Á, et al.

Materials & Design

BioTester

Hydrated and Temperature Controlled TestingTensile Testing

MechanotransductionVascular Tissue Engineering & Mechanics

2026

Contact Sales

Product of Interest: