PEER-REVIEWED PUBLICATION

2026

Anisotropic structure and mechanics of vaginal tissue in the rabbit

A tensile test divider icon

Torun SG, Sreedhar S, Amadio A, et al.

Acta Biomaterialia

The University of Texas at Austin, Texas A&M University, Baylor College of Medicine

RESEARCH SUMMARY
This study established a detailed structural and mechanical baseline for healthy rabbit vaginal tissue by combining planar biaxial testing with second harmonic generation imaging and anisotropic constitutive modeling. Twenty-seven 10 × 10 mm samples from the internal vaginas of four healthy adult New Zealand White rabbits were characterized across multiple anatomical regions. Collagen imaging showed that fibers were predominantly oriented along the longitudinal vaginal axis, with a median orientation of 87°, and although fiber orientation and dispersion varied regionally, neither varied significantly with tissue depth over the analyzed 30-220 µm range. Biaxial testing revealed nonlinear J-shaped and strongly anisotropic mechanical behavior. Toe stiffness did not differ significantly between directions, but high-stress calf stiffness was significantly greater longitudinally, with median values of 682.3 kPa longitudinally and 483.6 kPa circumferentially. Transition stretch was significantly higher circumferentially, and the median anisotropy index at 20 kPa was 1.10, indicating greater circumferential deformation at a common stress. The predominantly longitudinal collagen alignment was consistent with the greater longitudinal stiffness observed mechanically. The experimental data were subsequently fitted using anisotropic hyperelastic constitutive models combining a Holzapfel-Gasser-Ogden fiber term with either an Ogden or Neo-Hookean isotropic matrix. The Ogden-based formulation provided the stronger overall fit, with a median normalized mean square error of approximately 0.98 for individual samples. The authors provide what they describe as the first anisotropic hyperelastic material parameters for healthy rabbit vaginal tissue. These findings establish a quantitative reference for evaluating disease, pregnancy, injury, pelvic floor dysfunction, and biomaterial-device interactions in rabbit models and provide material parameters that can be incorporated into computational simulations of vaginal tissue and intravaginal devices.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

BioTester

A CellScale BioTester was used to perform planar biaxial mechanical testing on 27 healthy rabbit internal vaginal tissue specimens. On the day of testing, samples were thawed in a 37 °C water bath, rinsed in PBS, measured for thickness, and marked on the mucosal surface for optical strain tracking. Each approximately 10 × 10 mm specimen was mounted on the BioTester and submerged in 1× PBS maintained at 37 °C. A 50 mN preload was applied in both the circumferential and longitudinal directions to remove slack. Samples were then preconditioned within their elastic range for 20 cycles up to 1000 mN in both directions. Following preconditioning, the BioTester performed force-controlled biaxial testing using two cycles of five loading protocols: equibiaxial loading at 1000/1000 mN and four off-biaxial conditions of 750/1000, 1000/750, 500/1000, and 1000/500 mN in the circumferential/longitudinal directions. The maximum 1000 mN force was selected to generate large tissue deformations without causing damage. During testing, the system recorded force, rake displacement, and sample images every 200 ms. CellScale LabJoy software was used to track surface markers and calculate deformation relative to the stress-free configuration. BioTester measurements were converted to Cauchy stress-stretch relationships and used to calculate toe stiffness, high-stress calf stiffness, transition stretch, and an anisotropy index. The resulting data demonstrated significantly greater longitudinal calf stiffness than circumferential stiffness and greater circumferential stretch at equivalent stress, establishing clear mechanical anisotropy in healthy rabbit vaginal tissue. These BioTester-derived mechanical data were then integrated with collagen orientation measurements to derive structurally informed anisotropic hyperelastic material parameters for computational modeling.
AUTHORS

Su Guvenir Torun, Shreya Sreedhar, Alexandra Amadio, Ashley J. Hicks, Colton Kostelnik, Daniel Edward Kennedy II, Julie Hakim, W. Brian Saunders, Lauren K. Davis, Elizabeth Cosgriff-Hernandez, Manuel K. Rausch.

PUBLICATION DETAILS
JOURNAL

Acta Biomaterialia

YEAR

2026

INSTITUTIONS

The University of Texas at Austin, Texas A&M University, Baylor College of Medicine

COUNTRIES

United States

INSTRUMENT USED

BioTester

TESTING METHODS

Biaxial TestingDigital Image Correlation (DIC)Hydrated and Temperature Controlled Testing

RESEARCH APPLICATIONS

Pelvic Floor and Gynecological Biomechanics

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Effect of electron beam irradiation on the mechanical and solubility properties of nanofibrous electrospun polyurethane composite biomaterials

Webb CWB, Chen Y, D'Costa K, Santerre JP

Materials Letters

BioTester

Tensile Testing

Membranes and Thin Films MechanicsPolymers and Elastomers TestingScaffold Mechanical Testing

2027

Anisotropic structure and mechanics of vaginal tissue in the rabbit

Torun SG, Sreedhar S, Amadio A, et al.

Acta Biomaterialia

BioTester

Biaxial TestingDigital Image Correlation (DIC)Hydrated and Temperature Controlled Testing

Pelvic Floor and Gynecological Biomechanics

2026

Small Diameter Vascular Grafts Made in Minutes

Peters MM, Atrott K, Zorndt D, et al.

Advanced Materials

BioTester

Hydrated and Temperature Controlled TestingTensile Testing

Polymers and Elastomers TestingScaffold Mechanical TestingVascular Tissue Engineering & Mechanics

2026

Contact Sales

Product of Interest:
CellScale hexagon shapes