PEER-REVIEWED PUBLICATION

2026

A Portable and Dual-Button Microneedle Device Enables Intelligent Multimodal Laser Sensing

A tensile test divider icon

Liu Y, Hu X, Shi S, et al.

Advanced Science

City University of Hong Kong, National University of Singapore, Huazhong University of Science and Technology, Nanjing Tech University, Zhejiang Wanli University

RESEARCH SUMMARY
This study developed a portable dual-button microneedle device for rapid collection of interstitial fluid and subsequent multimodal molecular and elemental analysis. The system combines a reusable mechanical applicator with disposable SLA-printed hollow microneedles containing integrated microfluidic channels and an Au nanocube/MXene sensing module. Pressing the first button inserts the microneedles into skin, while a second button releases a spring-loaded mechanism to retract them after approximately one minute of sampling. Mechanical characterization showed reproducible artificial-skin penetration and demonstrated that microneedles incorporating an oblique channel design resisted compression more effectively than conventional straight-channel tips, with lower displacement at equivalent force. COMSOL simulations supported the experimental findings by showing reduced stress transfer into the thin channel wall of the oblique design. The microneedles successfully penetrated a 2% agarose artificial-skin model and approximately 600 µm into rat skin, with visible puncture marks largely resolving within about one hour. The collected interstitial fluid was analyzed using surface-enhanced Raman spectroscopy for molecular biomarkers and laser-induced breakdown spectroscopy for elemental biomarkers. The sensing platform showed strong calibration linearity for representative analytes including 6-mercaptopurine and lithium, while animal pharmacokinetic experiments demonstrated that temporal changes measured in interstitial fluid followed trends observed in plasma. A convolutional neural network combining SERS and LIBS data achieved an overall classification accuracy of 0.885, with precision, recall, and F1 scores of 0.887, 0.891, and 0.888, respectively. Overall, the study integrates mechanically robust 3D-printed microneedles, microfluidic sampling, multimodal laser spectroscopy, and AI-based data processing into a low-cost point-of-care platform for minimally invasive health and drug monitoring.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

UniVert

A CellScale UniVert mechanical testing system was used to characterize both the compressive mechanical performance of the 3D-printed hollow microneedle tips and the force-displacement response during penetration into an artificial-skin model. The authors compared microneedles containing a conventional straight microfluidic channel with a redesigned oblique channel. Force-displacement measurements showed that, at the same force per needle, the oblique-channel design underwent less displacement than the straight-channel design, indicating greater compressive resistance. The difference was further evaluated by comparing force at 1 mm displacement and was supported by COMSOL simulations showing that the straight channel transmitted stress into a thinner channel wall, whereas the oblique design concentrated stress within the thicker tip region. The CellScale system was also used while the microneedle device was inserted into artificial skin, producing a force-displacement curve with two characteristic points corresponding to initial skin penetration and complete penetration. These measurements helped verify that the redesigned microneedles possessed sufficient mechanical strength for reliable transdermal insertion and supported development of the dual-button device for rapid interstitial-fluid sampling.
AUTHORS

Yuanchao Liu, Xiujuan Hu, Shengqun Shi, Bowen Li, Zhixing Ge, Yunchen Long, Chaochao Sun, Annan Chen, Bingbing Gao, Lianbo Guo, Condon Lau, Wei Luo, Chwee Teck Lim.

PUBLICATION DETAILS
JOURNAL

Advanced Science

YEAR

2026

INSTITUTIONS

City University of Hong Kong, National University of Singapore, Huazhong University of Science and Technology, Nanjing Tech University, Zhejiang Wanli University

COUNTRIES

China, Singapore

INSTRUMENT USED

UniVert

TESTING METHODS

Compression TestingPuncture Testing

RESEARCH APPLICATIONS

Polymers and Elastomers TestingWearable Bioelectronics