Translating Plasticization-Responsive Shape Memory Polymers from Conventional Casting to High-Resolution Stereolithography for Custom Biomedical Devices

A tensile test divider icon

Pittala RK, Pilla S, Davange NP, et al.

Journal of Functional Biomaterials

University of North Texas

RESEARCH SUMMARY
This study translated water-responsive thiol-ene shape memory polymers from conventional casting to high-resolution stereolithography for the fabrication of customizable biomedical devices. TATATO/TMTMP polymer networks were conventionally cast using DMPA or TPO photoinitiators or adapted for SLA printing using TPO together with pyrogallol and, in one formulation, Sudan-1 to control photopolymerization and printing resolution. SLA successfully produced complex structures including tubular stents while maintaining the characteristic plasticization-responsive behavior of the polymer system. Mechanical testing showed substantial differences between the dry and hydrated states. Conventionally cast polymers reached dry Young’s moduli approaching 1.2 GPa, whereas SLA-printed formulations had lower dry moduli of approximately 80-125 MPa. After physiological hydration, all formulations softened markedly to approximately 5-15 MPa as absorbed water plasticized the network. Dry fracture strains ranged from approximately 40% to 75%, while hydrated specimens failed at approximately 12-15% strain. Cyclic tensile testing showed pronounced initial hysteresis in dry materials but minimal hysteresis and little permanent deformation in hydrated samples over repeated loading. Dynamic mechanical analysis confirmed that hydration lowered glass transition temperature, from 31-35 °C to 21-26 °C in cast polymers and from 17-23 °C to 10-15 °C in SLA-printed materials. Despite these changes, all formulations retained strong shape-memory performance, with approximately 98-100% unconstrained recovery in 37 °C water. SLA-printed formulations recovered particularly rapidly, within approximately 1.29-1.75 seconds. Swelling remained low, generally below approximately 1.6%, supporting dimensional stability. Cytocompatibility testing also showed viability above the ISO 10993-5 non-cytotoxicity threshold. Overall, the study demonstrates that plasticization-responsive thiol-ene shape memory polymers can be adapted to high-resolution SLA printing while retaining hydration-triggered softening and shape recovery, although the relatively low dry-state glass transition temperature of the printed formulations remains a limitation for storage and handling of future implantable devices.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

UniVert

A CellScale UniVert tensile tester was used to compare the tensile mechanical behavior of conventionally cast and stereolithography-printed thiol-ene shape memory polymers under both dry and physiologically hydrated conditions. Cast specimens were manually cut into ISO 527-2 type 5B dog-bone geometries, while SLA specimens were printed directly in the same geometry. All specimens had a gauge thickness of 0.25 ± 0.05 mm. Dry specimens were tested immediately after removal from a vacuum oven. For hydrated testing, specimens were equilibrated in PBS at 37 °C for four days and then mechanically tested inside a UniVert fluid submersion chamber at 37 °C. Dry pull-to-fracture tests used a 50 N load cell, while hydrated specimens used a 10 N load cell to improve resolution after plasticization reduced material stiffness and failure force. A 0.1 N preload was applied and specimens were stretched at 5 mm/min until fracture. Force-displacement measurements were used to calculate fracture strain and Young’s modulus, with modulus determined from the 1-5% strain region. UniVert testing showed that dry conventionally cast networks reached moduli approaching 1.2 GPa, whereas SLA-printed formulations were approximately 80-125 MPa. Following PBS hydration, all formulations softened substantially to approximately 5-15 MPa. The UniVert was also used for cyclic tensile characterization using independent specimens loaded at 16 mm/min with a 0.1 N preload and 10-second recovery between cycles. Dry samples were cycled to maximum strains of 12.5% or 30%, while hydrated samples were cycled in the 37 °C fluid chamber to 12.5-15% strain. Dry specimens displayed pronounced first-cycle hysteresis, while hydrated specimens showed minimal hysteresis over five cycles and nearly overlapping loading-unloading paths. These UniVert measurements demonstrated the strong water-induced plasticization of the thiol-ene networks and confirmed that SLA printing preserved useful tensile integrity and repeatable deformation behavior under physiologically relevant aqueous conditions.
AUTHORS

Raj Kumar Pittala, Sravya Pilla, Neha Pramod Davange, Marc Anthony Torres, Akhila Joy, Xiao Li, Melanie Ecker.

PUBLICATION DETAILS
JOURNAL

Journal of Functional Biomaterials

YEAR

2026

INSTITUTIONS

University of North Texas

COUNTRIES

United States

INSTRUMENT USED

UniVert

TESTING METHODS

Hydrated and Temperature Controlled TestingTensile Testing

RESEARCH APPLICATIONS

Polymers and Elastomers Testing

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Reduced cortical bone strength and altered osteocyte canaliculi despite preserved bone mass in male Becn1+/− mice

Pei Q, Qin X, He Y, et al.

Bone

UniVert

Flexural and Bending Testing

Bone Tissue Engineering & Mechanics

2027

Translating Plasticization-Responsive Shape Memory Polymers from Conventional Casting to High-Resolution Stereolithography for Custom Biomedical Devices

Pittala RK, Pilla S, Davange NP, et al.

Journal of Functional Biomaterials

UniVert

Hydrated and Temperature Controlled TestingTensile Testing

Polymers and Elastomers Testing

2026

Alginate scaffolds functionalized with calcium-stabilized cubic zirconia nanoparticles for periodontal tissue engineering

Santos MS, Ureña C, Rosa MT, et al.

Materials & Design

UniVert

Compression Testing

Bone Tissue Engineering & MechanicsDental & Oral Tissue BiomechanicsMechanotransductionScaffold Mechanical Testing

2026

Contact Sales

Product of Interest:
CellScale hexagon shapes