Improving the hemocompatibility of a porohyperelastic layered vascular graft using luminal reversal microflows

A tensile test divider icon

Behrangzade A, Ye SH, Maestas DR Jr, et al.

Journal of the Mechanical Behavior of Biomedical Materials

University of Pittsburgh, McGowan Institute for Regenerative Medicine, Vascular Medicine Institute

RESEARCH SUMMARY
This study developed bilayered porous vascular grafts designed to mechanically reduce platelet deposition through luminal reversal flow, a transient outward interstitial fluid flow generated from the graft wall during pressure unloading. The graft concept combined a thick, highly permeable and deformable electrospun Tecoflex SG-85 A inner layer with a thin, comparatively impermeable thermobonded polycaprolactone outer layer. Mechanical characterization of the individual tubular materials was used to identify porohyperelastic material properties for finite element modeling and guide fabrication of high- and low-LRF graft designs. Tecoflex was substantially more deformable than thermobonded PCL, reaching a circumferential stretch of approximately 1.12 compared with approximately 1.008 for thermobonded PCL under the same pressure range, and its tangential modulus was significantly lower. Porohyperelastic finite element simulations predicted luminal reversal flow values of -10.06 µm/s for the high-LRF design and -2.87 µm/s for the low-LRF design. When the bilayered grafts were exposed to fresh citrated ovine blood for 90 minutes under pulsatile flow, high-LRF grafts accumulated significantly fewer platelets than low-LRF grafts, with median platelet deposition of approximately 5,708 versus 23,039 platelets/mm². SEM imaging confirmed substantially less platelet accumulation on the high-LRF luminal surfaces. Overall, the approximately 250% increase in predicted LRF was associated with a 75.2% reduction in platelet deposition, supporting luminal reversal microflow as a mechanical strategy for improving the hemocompatibility of small-diameter vascular grafts without relying solely on chemical antithrombotic surface modification.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

Custom CellScale Tubular Testing System

A custom CellScale tubular mechanical testing system, described in this publication as a ‘custom-made microbiaxial tensile testing device,’ was used to mechanically characterize single-layer tubular electrospun Tecoflex SG-85 A and thermobonded polycaprolactone constructs. This is the earlier publication from the same University of Pittsburgh research group using the custom CellScale tubular testing platform. Three specimens of each material were cut into 1-1.5 cm tubular segments, cannulated onto metallic capillary tubes, sutured, and glued at both ends. The CellScale testing chamber was filled with water and maintained at 37 °C. The graft inlet was connected to a water-filled hydraulic piston and pressure line, while the outlet was blocked to create closed-end pressurization. A pressure transducer monitored intraluminal pressure, a load cell measured axial load, and the system camera tracked outer diameter. Specimens underwent 10 loading-unloading cycles between 0 and 120 mmHg, with the first nine serving as preconditioning and the final cycle used to calculate circumferential Cauchy stress-stretch behavior. The axial position was fixed during testing and no axial displacement was imposed. CellScale measurements showed that electrospun Tecoflex was substantially more compliant than thermobonded PCL: maximum circumferential stretch was approximately 1.12 for Tecoflex and 1.008 for thermobonded PCL, and Tecoflex had a significantly lower tangential modulus. These experimentally measured responses were used to identify Neo-Hookean material parameters for the study’s porohyperelastic finite element model, which subsequently predicted luminal reversal flow and compliance in the bilayered high- and low-LRF vascular graft designs.
AUTHORS

Ali Behrangzade, Sang-Ho Ye, David R. Maestas Jr., William R. Wagner, Jonathan P. Vande Geest.

PUBLICATION DETAILS
JOURNAL

Journal of the Mechanical Behavior of Biomedical Materials

YEAR

2024

INSTITUTIONS

University of Pittsburgh, McGowan Institute for Regenerative Medicine, Vascular Medicine Institute

COUNTRIES

United States

INSTRUMENT USED

Custom CellScale Tubular Testing System

TESTING METHODS

Hydrated and Temperature Controlled TestingPressure Testing

RESEARCH APPLICATIONS

Polymers and Elastomers TestingScaffold Mechanical TestingVascular Tissue Engineering & Mechanics