PEER-REVIEWED PUBLICATION

2025

Substrate stiffness modulates phenotype-dependent fibroblast contractility and migration independent of TGF-β stimulation

D'Urso M, van den Bersselaar P, et al.

Mechanobiology in Medicine

Eindhoven University of Technology, Université de Montpellier, University of Naples Federico II

RESEARCH SUMMARY
Fibroblast phenotype, contractility, and migration are governed by substrate stiffness—even overruling classical TGF-β stimulation. Using human dermal fibroblasts on soft (~9 kPa) and stiff (~30 kPa) polyacrylamide gels, the authors show that stiff microenvironments drive stress-fiber formation, focal-adhesion (FA) maturation, αSMA incorporation, and reduced motility in fully transitioned myofibroblasts. Traction force microscopy revealed ~101 Pa mean tractions on soft vs. ~270 Pa on stiff substrates; TGF-β increased forces on soft gels but slightly decreased them on stiff gels. Single-cell tracking showed higher migration speeds on stiff substrates (e.g., ~0.56 μm/min at 96 h) than on soft (~0.32 μm/min), while TGF-β decreased speed on stiff gels as cells completed FMT. FA morphology depended on stiffness (round on soft, elongated on stiff) and TGF-β further enlarged FAs only on stiff gels. Figures highlight cytoskeletal/FA remodeling (Fig. 1, p. 4), migration trajectories and MSD (Fig. 2, pp. 5–6), traction vector maps (Fig. 3A, p. 6) and FA size/speed distributions (Fig. 4B–C, p. 7). Conclusion: stiffness mechanosensing is a primary regulator of fibroblast-to-myofibroblast transition and phenotype-dependent migration/contractility, with implications for fibrosis and wound repair.

CELLSCALE INSTRUMENT USED

MicroTester

Hydrogel stiffnesses used in the study were quantified by indentation with a CellScale MicroTester. Tests were performed in PBS immersion at 37 °C using a spherical indenter (R = 0.5 mm), constant speed 15 μm/s, and 200 μm displacement (~5% of sample thickness). Each sample was measured ≥3 times (≥3 samples/group). Young’s modulus was computed from loading curves by Hertzian contact (spherical) assuming incompressibility (ν = 0.5), using a MATLAB routine adapted from Huth et al. (2019). This MicroTester protocol provided the calibrated stiffness inputs (soft ≈ 9.3 ± 1.6 kPa; stiff ≈ 33.3 ± 6.1 kPa) that anchored downstream FA, traction, and migration analyses.
AUTHORS

Mirko D’Urso, Pim van den Bersselaar, Sarah Pragnere, Paolo Maiuri, Carlijn V.C. Bouten, Nicholas A. Kurniawan.

PUBLICATION DETAILS
JOURNAL

Mechanobiology in Medicine

YEAR

2025

INSTITUTIONS

Eindhoven University of Technology, Université de Montpellier, University of Naples Federico II

COUNTRIES

France, Italy, Netherlands

INSTRUMENT USED

MicroTester

TESTING METHODS

Hydrated and Temperature Controlled TestingIndentation Testing

RESEARCH APPLICATIONS

ECM & Decellularized Matrix MechanicsFibrosis & Tissue RemodelingMechanotransductionSkin and Wound Healing Biomechanics

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Development of open-source in situ photocrosslinking printhead attachments for extrusion bioprinting of hydrogel matrices

Weekes A, Stevenson M, et al.

Bioprinting

MicroTester

Compression TestingMicro-Mechanical Testing

3D Bioprinting & Bioink Materials TestingHydrogel Mechanical TestingStem Cell Mechanobiology

2026

Enabling dual excitation-contraction recording and disease modeling via hydrogel-free heart tissue

Li J, Liu Y, et al.

Cell Reports Physical Science

MicroTester

Compression TestingMicro-Mechanical TestingUltra Low Force Testing

Cardiac Tissue Engineering & MechanicsDrug Screening & Drug Delivery MechanicsOrgan-On-A-Chip Systems

2026

Exploring Injectable Scaffolded Spheroids for Nucleus Pulposus Therapy in Degenerated Intervertebral Discs

Balasubramanian R V, Muerner M, et al.

ACS Applied Materials & Interfaces

MicroTester

Compression TestingHydrated and Temperature Controlled TestingMicro-Mechanical Testing

Injectable & Regenerative BiomaterialsIntervertebral Disc BiomechanicsMicrotissue and Spheroid MechanicsScaffold Mechanical Testing

2026

Contact Sales

Product of Interest: