PEER-REVIEWED PUBLICATION

2026

Lipid Peroxidation Increases Lens Stiffness and Is Associated With αA-Crystallin Accumulation at the Plasma Membrane: An Ex Vivo Study

A tensile test divider icon

Fan E, Hao C, Zheng S, et al.

Investigative Ophthalmology & Visual Science

Augusta University, Medical College of Georgia; University of Georgia, Franklin College of Arts and Sciences

RESEARCH SUMMARY
This study developed a long-term ex vivo mouse lens culture model and investigated whether lipid peroxidation directly contributes to cataract-associated changes in lens transparency, light scattering, mechanical stiffness, and protein biochemistry. Intact lenses from 3-month-old C57BL/6J mice remained transparent for at least two weeks in culture. Lipid peroxidation was induced either by inhibiting glutathione peroxidase 4 with RSL3 or by depleting glutathione using buthionine sulfoximine combined with dimethyl fumarate. Both treatments increased 4-hydroxynonenal formation and produced progressive lens opacity. RSL3-treated lenses developed mild opacity by day 9 and dense nuclear opacity by day 12, while BSO/DMF-treated lenses developed similar changes beginning around day 8. Spectrophotometric measurements showed increased visible-light absorbance and light scattering after lipid-peroxidation induction, and the lipid-peroxidation inhibitor liproxstatin-1 markedly reduced these optical changes. Mechanical testing demonstrated that lipid peroxidation also increased lens stiffness: RSL3 produced a significant increase by 120 hours of culture, while BSO/DMF significantly increased stiffness after 168 hours. Biochemical analysis showed increased association of αA-crystallin and its alternatively spliced αAIns form with native lens membrane fractions, together with increased formation of high-molecular-weight protein aggregates. The authors conclude that lipid peroxidation is sufficient to produce cataract-relevant lens stiffening and opacification in an intact ex vivo lens model and is associated with altered crystallin-membrane interactions and protein aggregation. The findings connect oxidative membrane damage with both optical deterioration and the biomechanical stiffening associated with lens aging and presbyopia, while noting that protein oxidation and other parallel oxidative mechanisms may also contribute to the observed effects.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

MicroTester

A CellScale MicroTester LT was used to measure the mechanical stiffness of intact ex vivo mouse lenses following induction of lipid peroxidation. Individual lenses were placed on the MicroTester platform in the anterior-posterior orientation and compressed using a 3 × 3 mm flat platen mounted on a 0.3048 mm diameter cantilever beam. Each lens was compressed once to 15% axial deformation while force and displacement were recorded. After reaching the target displacement and maximum applied force, the platen position was held for 3 seconds before gradually withdrawing to allow the lens to recover its original shape. Lens stiffness was calculated from the slope of the linear portion of the force-displacement curve and expressed in N/m. At least eight lenses were analyzed per experimental group at each time point. MicroTester measurements showed that RSL3-mediated GPX4 inhibition progressively increased lens stiffness, with a statistically significant increase after 120 hours of culture. Glutathione depletion using BSO plus DMF similarly increased lens stiffness, reaching significance after 168 hours. These mechanical measurements provided direct evidence that experimentally induced lipid peroxidation is sufficient to stiffen the intact crystalline lens and linked oxidative membrane damage with a major biomechanical feature of lens aging and presbyopia.
AUTHORS

Emily Fan, Caili Hao, Shuyu Zheng, Ming Zhang, Xingjun Fan.

PUBLICATION DETAILS
JOURNAL

Investigative Ophthalmology & Visual Science

YEAR

2026

INSTITUTIONS

Augusta University, Medical College of Georgia; University of Georgia, Franklin College of Arts and Sciences

COUNTRIES

United States

INSTRUMENT USED

MicroTester

TESTING METHODS

Compression TestingMicro-Mechanical Testing

RESEARCH APPLICATIONS

Ophthalmic Biomechanics & Corneal Tissue Engineering

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Cell-generated forces recapitulate geometry-defined deformation modes in auxetic and non-auxetic micro-architected scaffolds

Parlanis A, Farsari M, Ranella A

Cell Reports Physical Science

MicroTester

Compression TestingMicro-Mechanical Testing

Scaffold Mechanical TestingStem Cell Mechanobiology

2026

A Multi-Crosslinkable Methacrylated Alginate-GelMa Bioink for Drop-on-Demand Bioprinting

Bui T, Karakaya E, Faber J, et al.

Macromolecular Bioscience

MicroTester

Compression TestingHydrated and Temperature Controlled TestingMicro-Mechanical Testing

3D Bioprinting & Bioink Materials TestingCell Laden HydrogelsHydrogel Mechanical Testing

2026

The nonlinear mechanics of single electrospun polyurethane fibers under wet and dry conditions

Madariaga A, Lohr MJ, Beck JL, et al.

Soft Matter

MicroTester

Flexural and Bending TestingMicro-Mechanical TestingViscoelastic & Time-Dependent Testing

Material Fatigue and DurabilityPolymers and Elastomers Testing

2026

Contact Sales

Product of Interest:
CellScale hexagon shapes