PEER-REVIEWED PUBLICATION

2018

Urinary Bladder vs Gastrointestinal Tissue: A Comparative Study of Their Biomechanical Properties for Urinary Tract Reconstruction

Davis N, Mulvihill J, et al.

Urology

The Austin Hospital, University of Limerick

RESEARCH SUMMARY
This study performed a comparative biomechanical analysis of urinary bladder and gastrointestinal (GI) tissues to evaluate their suitability for urinary tract reconstruction. Using porcine models, planar tension tests were carried out on the bladder, stomach, jejunum, ileum, cecum, and colonic segments. Stress–stretch data revealed that bladder tissue exhibits a significantly more compliant response than GI segments, with higher strain at given stress and lower Young’s modulus. GI tissues were markedly stiffer and less distensible; only the stomach approached bladder compliance. Directional testing confirmed that bladder tissue is nearly isotropic, whereas GI segments were moderately anisotropic. Results indicate that bladder tissue’s elastic distensibility enables low-pressure volume expansion not achievable by GI substitutes. The authors concluded that autologous GI tissue is mechanically unsuited for durable bladder replacement, motivating biomaterials that better replicate bladder mechanics.

CELLSCALE INSTRUMENT USED

BioTester

Mechanical characterization of bladder and gastrointestinal tissues was conducted using a dedicated CellScale mechanical testing system designed for biological soft tissues. The CellScale device enabled precise uniaxial planar tensile testing under hydrated, temperature-controlled conditions (PBS at 37 °C), allowing accurate measurement of stretch–stress behavior, anisotropy, and stiffness across tissue types. Cyclic loading protocols implemented on the CellScale platform minimized viscoelastic artifacts and strain softening, ensuring reliable comparison of mechanical properties critical for evaluating candidate biomaterials for urinary bladder replacement.
AUTHORS

N.F. Davis, J.J.E. Mulvihill, S. Mulay, E.M. Cunnane, D.M. Bolton, M.T. Walsh.

PUBLICATION DETAILS
JOURNAL

Urology

YEAR

2018

INSTITUTIONS

The Austin Hospital, University of Limerick

COUNTRIES

Australia, Ireland

INSTRUMENT USED

BioTester

TESTING METHODS

Hydrated and Temperature Controlled TestingMicro-Mechanical TestingTensile TestingViscoelastic & Time-Dependent Testing

RESEARCH APPLICATIONS

ECM & Decellularized Matrix MechanicsGastrointestinal and Urinary Tract BiomechanicsInjectable & Regenerative Biomaterials

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

A Versatile Engineering Platform for the Fabrication of Prosthetic Venous Valves Using Electrospinning

Arcuti D, Mansi S, et al.

Advanced Healthcare Materials

BioTester

Biaxial Testing

Heart Valve Tissue Engineering & MechanicsPolymers and Elastomers TestingVascular Tissue Engineering & Mechanics

2026

Viscoelastic Properties of Porcine Pericardium Under Biaxial Tensile Creep and Stress Relaxation: Application for Novel Aortic Valve Bioprosthesis Design

Matjeka E, Kuchumov A G, et al.

Bioengineering

BioTester

Biaxial TestingCreep TestingHydrated and Temperature Controlled TestingStress Relaxation Testing

Cardiac Tissue Engineering & MechanicsHeart Valve Tissue Engineering & Mechanics

2026

The Biomechanical Properties of Porcine Intervertebral Disc Tissue Treated with Different Fixation Solutions

Chow N, Sinopoli SI, et al.

Journal of the Mechanical Behavior of Biomedical Materials

BioTesterUStretch

Peel TestingTensile Testing

Intervertebral Disc Biomechanics

2026

Contact Sales

Product of Interest: