PEER-REVIEWED PUBLICATION

2016

Planar Biaxial Testing of Heart Valve Cusp Replacement Biomaterials: Experiments, Theory, and Material Constants

Labrosse MR, Jafar R, et al.

Acta Biomaterialia

University of Ottawa, University of Ottawa Heart Institute

RESEARCH SUMMARY
This study performed comprehensive planar biaxial mechanical characterization of clinically relevant aortic valve cusp replacement biomaterials and native porcine valve leaflets. Using a multi-protocol biaxial testing framework, the authors quantified nonlinear anisotropic stress–strain behavior and identified material constants for two Fung-type constitutive models. Among the six replacement materials evaluated, CardioCel and Supple PeriGuard most closely matched the mechanical response of young native valve leaflets, while PeriGuard best approximated aged tissue. The results demonstrate that mechanical anisotropy and stiffness matching are critical design criteria for durable aortic valve repair.

CELLSCALE INSTRUMENT USED

BioTester

Planar biaxial mechanical testing was conducted using a CellScale BioTester system to apply controlled orthogonal tensile displacements to native valve leaflets and cusp replacement biomaterials. The CellScale device enabled precise displacement-controlled loading across multiple biaxial protocols while maintaining tissue hydration and temperature control, allowing robust measurement of anisotropic stress–strain behavior. Integrated imaging and custom data processing supported accurate strain calculation and material parameter identification. CellScale biaxial testing was central to establishing mechanical equivalence between replacement patches and native valve tissue, directly informing material selection strategies for aortic valve repair.
AUTHORS

Michel R. Labrosse, Reza Jafar, Janet Ngu, Munir Boodhwani.

PUBLICATION DETAILS
JOURNAL

Acta Biomaterialia

YEAR

2016

INSTITUTIONS

University of Ottawa, University of Ottawa Heart Institute

COUNTRIES

Canada

INSTRUMENT USED

BioTester

TESTING METHODS

Biaxial TestingHydrated and Temperature Controlled TestingMicro-Mechanical TestingTensile TestingViscoelastic & Time-Dependent Testing

RESEARCH APPLICATIONS

ECM & Decellularized Matrix MechanicsHeart Valve Tissue Engineering & MechanicsPolymers and Elastomers Testing

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Postpartum biomechanical adaptations of the anterior abdominal wall in a rat model: Implications for diastasis rectus abdominis

Lax M, Morgan M, et al.

Clinical Biomechanics

BioTester

Tensile Testing

Musculoskeletal Tissue Engineering & MechanicsPelvic Floor and Gynecological Biomechanics

2026

Comparison of Mechanical Properties of Patient-Specific Direct 3D-Printed Aortic Valve for Simulation Trainings: A Comparative Study

Cheheili Sobbi S, Pavlykova-Chertovska A, et al.

Innovations

BioTester

Digital Image Correlation (DIC)Tensile Testing

Cardiac Tissue Engineering & MechanicsHeart Valve Tissue Engineering & MechanicsPolymers and Elastomers Testing

2026

A deep neural network surrogate for fast mechanical parameter identification using the ring tensile test

Utrera A, Navarrete Á, et al.

Materials & Design

BioTester

Hydrated and Temperature Controlled TestingTensile Testing

MechanotransductionVascular Tissue Engineering & Mechanics

2026

Contact Sales

Product of Interest: