PEER-REVIEWED PUBLICATION

2025

Human heart-on-a-chip model emulates structural and functional characteristics of diastolic dysfunction and reveals a beneficial role for senolytics

A tensile test divider icon

Mourad O, Masse S, et al.

Acta Biomaterialia

University Health Network, University of Toronto, Hospital for Sick Children

RESEARCH SUMMARY
This study developed a human heart-on-a-chip (HOC) model of diastolic dysfunction (DD), a core feature of HFpEF, using Biowire-style engineered cardiac microtissues formed from human pluripotent stem cell-derived cardiomyocytes and cardiac fibroblasts. DD was induced by treating HOCs with endothelin-1 and TGF-β, which increased passive tension ~3-fold while preserving active contractile force. Disease tissues displayed cardiomyocyte hypertrophy, diffuse interstitial fibrosis (increased collagen deposition and lysyl oxidase expression), impaired calcium handling, and slowed relaxation. Drug testing demonstrated that empagliflozin did not improve the DD phenotype, whereas the senolytic combination dasatinib + quercetin and ranolazine partially reversed or prevented passive-tension abnormalities (with timing-dependent efficacy), supporting this platform for mechanistic studies and therapeutic screening in DD/HFpEF.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

MicroTester

A CellScale MicroTester G2 was used to mechanically characterize the flexible PDMS rods that serve as force-sensing elements in the heart-on-a-chip device. For 3-point bending (reported as 3-point tension testing), each PDMS rod was fixed across a bridge fixture with 2 mm spacing to match the chip geometry. A circular-tipped beam attached to the MicroTester’s Z-axis actuator was aligned at the rod midpoint and driven downward at a constant speed to deflect the rod by 250 µm, held for 1 second, and then returned to the resting position. The protocol was repeated three times for each of six rod samples across batches to verify rod stiffness consistency and calibrate batch-to-batch variability for subsequent passive-tension/force calculations in the HOC assays.
AUTHORS

Mourad, O., Massé, S., Subha, T., Mirshafiei, F., Plakhotnik, J., Suthiwanich, K., Sun, X., Maynes, J.T., Nanthakumar, K., Nunes, S.S..

PUBLICATION DETAILS
JOURNAL

Acta Biomaterialia

YEAR

2025

INSTITUTIONS

University Health Network, University of Toronto, Hospital for Sick Children

COUNTRIES

Canada

INSTRUMENT USED

MicroTester

TESTING METHODS

Flexural and Bending TestingUltra Low Force Testing

RESEARCH APPLICATIONS

Cardiac Tissue Engineering & MechanicsDrug Screening & Drug Delivery MechanicsOrgan-On-A-Chip Systems

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Bioprinting of a human neuron model for quantifying pollutant toxicity

Yao E, Chen S, Lu G, Sun C, Nguyen QT

International Journal of Bioprinting

MicroTester

Compression TestingMicro-Mechanical Testing

3D Bioprinting & Bioink Materials TestingHydrogel Mechanical TestingNeural Tissue & CNS MechanicsOrganoid and Tissue Mimetic Systems

2026

Biomechanics and composition of fixed neurocranial tessellated cartilage from the neurocranium of four mobulid ray species with different depth ranges

Hinrichs T, Zhong J, Chang CW, et al.

Journal of the Royal Society Interface

MicroTester

Hydrated and Temperature Controlled TestingIndentation TestingMicro-Mechanical Testing

Cartilage and Meniscus Mechanics

2026

FGF-2 signaling dominance in TGF-β1/FGF-2–primed nasoseptal chondrocytes for cartilage tissue engineering

Ma Z, Grimes K, et al.

Journal of Tissue Engineering

MicroTester

Compression TestingMicro-Mechanical TestingStress Relaxation TestingViscoelastic & Time-Dependent Testing

Cartilage and Meniscus MechanicsMicrotissue and Spheroid Mechanics

2026

Contact Sales

Product of Interest: