PEER-REVIEWED PUBLICATION

2023

Evaluation of pliable bioresorbable, elastomeric aortic valve prostheses in sheep during 12 months post implantation

Vis A, de Kort BJ, et al.

Communications Biology

Eindhoven University of Technology, Erasmus MC, University of Amsterdam, University Medical Center Utrecht, SyMO-Chem BV

RESEARCH SUMMARY
This preclinical study evaluated the in vivo functionality and remodeling behavior of bioresorbable, pliable elastomeric heart valve prostheses fabricated from bis-urea-modified polycarbonate (PC-BU). Implanted in the aortic position of sheep for up to 12 months, the valves were assessed for durability, calcification, cell colonization, and tissue formation. Most valves remained pliable and structurally intact, free of thrombotic or calcific complications, though some exhibited cusp thickening or perforations. Histological analysis revealed limited cell infiltration and collagen deposition mainly in hinge regions, with minimal scaffold resorption. These findings demonstrate partial success in creating functional in situ tissue-engineered aortic valves, highlighting the challenge of achieving balanced tissue regeneration under systemic pressure.

CELLSCALE INSTRUMENT USED

BioTester

The mechanical behavior of explanted valve leaflets was evaluated using a CellScale BioTester 5000. Square samples (5 × 5 mm²) from the tip and belly regions of the valves were subjected to biaxial tensile testing in radial and circumferential directions using a 1.5 N load cell and LabJoy software v8.01. Strain was incremented in 5% steps up to 40%, with nine preconditioning cycles and one measurement cycle per step. Stress–strain curves and tangent moduli at 35% strain showed similar behavior to pre-implant materials, confirming mechanical stability after 12 months in vivo.
AUTHORS

Annemijn Vis, Bente J. de Kort, Wojciech Szymczyk, Jan Willem van Rijswijk, Sylvia Dekker, Rob Driessen, Niels Wijkstra, Paul F. Gründeman, Hans W. M. Niessen, Henk M. Janssen, Serge H. M. Söntjens, Patricia Y. W. Dankers, Anthal I. P. M. Smits, Carlijn V. C. Bouten, Jolanda Kluin.

PUBLICATION DETAILS
JOURNAL

Communications Biology

YEAR

2023

INSTITUTIONS

Eindhoven University of Technology, Erasmus MC, University of Amsterdam, University Medical Center Utrecht, SyMO-Chem BV

COUNTRIES

Netherlands

INSTRUMENT USED

BioTester

TESTING METHODS

Biaxial TestingTensile Testing

RESEARCH APPLICATIONS

Cardiac Tissue Engineering & MechanicsECM & Decellularized Matrix MechanicsFibrosis & Tissue RemodelingHeart Valve Tissue Engineering & Mechanics

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Postpartum biomechanical adaptations of the anterior abdominal wall in a rat model: Implications for diastasis rectus abdominis

Lax M, Morgan M, et al.

Clinical Biomechanics

BioTester

Tensile Testing

Musculoskeletal Tissue Engineering & MechanicsPelvic Floor and Gynecological Biomechanics

2026

Comparison of Mechanical Properties of Patient-Specific Direct 3D-Printed Aortic Valve for Simulation Trainings: A Comparative Study

Cheheili Sobbi S, Pavlykova-Chertovska A, et al.

Innovations

BioTester

Digital Image Correlation (DIC)Tensile Testing

Cardiac Tissue Engineering & MechanicsHeart Valve Tissue Engineering & MechanicsPolymers and Elastomers Testing

2026

A deep neural network surrogate for fast mechanical parameter identification using the ring tensile test

Utrera A, Navarrete Á, et al.

Materials & Design

BioTester

Hydrated and Temperature Controlled TestingTensile Testing

MechanotransductionVascular Tissue Engineering & Mechanics

2026

Contact Sales

Product of Interest: