PEER-REVIEWED PUBLICATION

2025

Effect of Skeletal Muscle Immobilization on Regional Anisotropic Viscohyperelastic Properties Change in a Rat Model

A tensile test divider icon

Simon C, Rekik S, et al.

IRBM

Université Paris - Est Créteil

RESEARCH SUMMARY
This study investigated the regional effects of skeletal muscle immobilization on anisotropic viscohyperelastic behavior using an in vitro rat model. Equibiaxial relaxation tests were performed on distal, medial, and proximal regions of immobilized biceps brachii samples to quantify regional differences in stiffness and relaxation. The results showed that immobilization primarily affected viscoelastic parameters—leading to increased relaxation coefficients—while the excising zone determined hyperelastic stiffness. Histological analysis revealed significant atrophy and fibrosis characterized by increased perimysium and endomysium collagen fractions. These mechanical and structural correlations suggest that immobilization-induced remodeling alters muscle anisotropy and viscoelasticity, with implications for spastic myopathy and rehabilitation research.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

BioTester

Equibiaxial relaxation tests were conducted using a CellScale BioTester with orthogonal traction axes. Biceps brachii samples were mounted in a saline bath at 26 ± 1 °C and subjected to 30 % biaxial strain followed by a 300 s relaxation phase. The BioTester precisely controlled preloading (30 mN per axis) and tracked stress–strain responses, enabling identification of viscohyperelastic parameters via anisotropic strain energy and Maxwell modeling. This setup provided quantitative insights into how short-position immobilization altered muscle stiffness and relaxation dynamics.
AUTHORS

Clément Simon, Sonia Rekik, Mustapha Zidi.

PUBLICATION DETAILS
JOURNAL

IRBM

YEAR

2025

INSTITUTIONS

Université Paris - Est Créteil

COUNTRIES

France

INSTRUMENT USED

BioTester

TESTING METHODS

Biaxial TestingHydrated and Temperature Controlled TestingStress Relaxation TestingTensile TestingViscoelastic & Time-Dependent Testing

RESEARCH APPLICATIONS

Fibrosis & Tissue RemodelingMechanotransductionMusculoskeletal Tissue Engineering & MechanicsSkeletal Muscle & Volumetric Muscle Loss

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Development of Large-Diameter Tissue-Engineered Vascular Grafts as an Alternative to Synthetic Conduits for Emergency Large-Vessel Trauma Reconstruction: A Preliminary Study

Lăpădatu BI, Ciucanu CC, Mureșan A, et al.

Journal of Cardiovascular Emergencies

BioTester

Tensile Testing

ECM & Decellularized Matrix MechanicsScaffold Mechanical TestingVascular Tissue Engineering & Mechanics

2026

Small Diameter Vascular Grafts Made in Minutes

Peters MM, Atrott K, Zorndt D, et al.

Advanced Materials

BioTester

Hydrated and Temperature Controlled TestingTensile Testing

Polymers and Elastomers TestingScaffold Mechanical TestingVascular Tissue Engineering & Mechanics

2026

Enhancing the stability of silicon anodes using polymer binders based on host-guest and hydrogen-bonding interactions: Do small changes in guest tether length matter?

Martín-Trasancos R, Montero-Alejo AL, Ortiz MG, et al.

European Polymer Journal

BioTester

Peel TestingTensile Testing

Adhesives and Sealants TestingPolymers and Elastomers Testing

2026

Contact Sales

Product of Interest:
CellScale hexagon shapes