Effect of electron beam irradiation on the mechanical and solubility properties of nanofibrous electrospun polyurethane composite biomaterials

A tensile test divider icon

Webb CWB, Chen Y, D'Costa K, Santerre JP

Materials Letters

University of Toronto

RESEARCH SUMMARY
This study investigated how electron-beam irradiation used for biomaterial sterilization affects the mechanical performance and solvent stability of electrospun polyurethane-based tissue-engineering scaffolds. Two nanofibrous scaffold formulations were evaluated: a synthetic degradable polar/hydrophobic/ionic polyurethane and polycarbonate urethane composite (D-PHI/PCNU), and a GelMA-containing faster-degrading D-PHI/PCNU composite referred to as LGD. Samples were exposed to a target electron-beam dose of 30 kGy and compared with non-irradiated controls. Scanning electron microscopy showed that irradiation did not significantly alter scaffold fiber morphology. Mechanical testing of PBS-conditioned scaffolds showed that e-beam exposure significantly increased ultimate tensile strength in both material formulations. Elastic modulus also increased significantly in D-PHI/PCNU scaffolds, while LGD showed a similar increase that did not reach statistical significance. Elongation at break was not significantly changed by irradiation, indicating that the increase in strength did not produce a corresponding loss of extensibility. Acetone-solubility testing showed no statistically significant change in mass loss following irradiation, although both formulations exhibited a trend toward reduced solubility. The authors conclude that 30 kGy e-beam irradiation can preserve or enhance important mechanical properties of electrospun polyurethane composite scaffolds without significantly changing their solvent stability. The findings support electron-beam treatment as both a viable sterilization approach and a potential post-fabrication method for mechanically tuning polymeric tissue-engineering materials, while emphasizing that irradiation effects depend on material composition and should be characterized for each scaffold formulation.
CellScale hexagons, without text

CELLSCALE INSTRUMENT USED

BioTester

A CellScale BioTester equipped with a 2.5 N load cell was used to perform uniaxial tensile testing to failure on electrospun D-PHI/PCNU and GelMA-containing LGD composite scaffolds before and after electron-beam irradiation. Scaffold strips measuring 4 mm by 38 mm were first incubated overnight in PBS at 37 °C. The wetted samples were then mounted longitudinally in the BioTester with the aligned electrospun fibers oriented along the loading direction and pulled apart at 166 µm/s until failure. Five specimens were tested per group. Scaffold thickness was determined separately by scanning electron microscopy and averaged approximately 10.8 ± 1.2 µm for D-PHI/PCNU and 10.0 ± 3.0 µm for LGD. BioTester stress-strain data were used to calculate ultimate tensile strength, elongation at break, and elastic modulus, with modulus determined from the initial linear region at 5-10% strain for D-PHI/PCNU and 5-15% strain for LGD. The measurements showed that 30 kGy electron-beam irradiation significantly increased ultimate tensile strength in both scaffold formulations. Irradiation also significantly increased elastic modulus in D-PHI/PCNU, while the LGD formulation showed an increase that was not statistically significant. Elongation at break remained unchanged in both materials. These BioTester measurements provided the primary evidence that e-beam sterilization can improve the tensile strength and, depending on formulation, stiffness of electrospun polyurethane composite scaffolds without reducing their extensibility.
AUTHORS

C.W. Brian Webb, Yizhou Chen, Katya D'Costa, J. Paul Santerre.

PUBLICATION DETAILS
JOURNAL

Materials Letters

YEAR

2027

INSTITUTIONS

University of Toronto

COUNTRIES

Canada

INSTRUMENT USED

BioTester

TESTING METHODS

Tensile Testing

RESEARCH APPLICATIONS

Membranes and Thin Films MechanicsPolymers and Elastomers TestingScaffold Mechanical Testing

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Contact Sales

Product of Interest:
CellScale hexagon shapes