PEER-REVIEWED PUBLICATION

2025

Modulating Rheological Properties via Non‑Cross‑Linked Phase in Biphasic Hyaluronic Acid Fillers

Buyukuysal OG, Caglar Z, et al.

ACS Omega

Hacettepe University

RESEARCH SUMMARY
This study develops biphasic hyaluronic acid (HA) dermal filler formulations that combine a cross-linked HA microparticulate phase with a citric-acid–modified non-cross-linked HA phase to tune rheological behavior while reducing reliance on more toxic cross-linking chemistries. The authors prepared non-cross-linked HA fractions (23 mg/mL) modified with 4–12% (w/w) citric acid (CA) and a cross-linked HA gel synthesized using 6% (w/w) BDDE, which was then microparticulated. These phases were reconstituted at 5–15% (w/w) non-cross-linked fraction to generate 15 biphasic gels and evaluate how CA content and steam sterilization influence material properties. Rheology (cone–plate rheometry at 37 °C) showed that biphasic formulations exhibited more solid-like viscoelastic behavior than either phase alone, and steam sterilization generally reduced elastic modulus—except for the optimized formulation BP-E-10-S, which retained favorable rheology (reported G′, G″, complex viscosity, and phase angle values) and was selected as the final candidate. Biocompatibility testing demonstrated high L929 cell viability and nonirritant in vivo implantation outcomes per ISO 10993 standards, supporting the formulation’s safety profile for soft tissue augmentation applications.

CELLSCALE INSTRUMENT USED

UniVert

A CellScale UniVert Biomaterial Tester was used to perform a cohesivity (cohesiveness) “drop-test” style assessment under constant compression, in which gel samples were loaded via syringe between load cells and driven at a controlled speed until rupture/strand breakup. This UniVert-based cohesivity testing provided a mechanical integrity metric complementary to rheology, helping the authors quantify how CA-modified non-cross-linked fractions and biphasic architectures influence gel structural cohesion—an important functional parameter for dermal fillers related to shape retention, integrity under handling/injection, and resistance to fragmentation in tissue.
AUTHORS

Buyukuysal O G; Caglar Z; Ozgen A; Aydin H M.

PUBLICATION DETAILS
JOURNAL

ACS Omega

YEAR

2025

INSTITUTIONS

Hacettepe University

COUNTRIES

Turkey

INSTRUMENT USED

UniVert

TESTING METHODS

Compression Testing

RESEARCH APPLICATIONS

Hydrogel Mechanical TestingInjectable & Regenerative BiomaterialsPolymers and Elastomers Testing

Related Publications:

Instrument Used:
Year:
Testing Method:
Research Application:
Country:

Controlling the Bioprinting Efficiency of Alginate–Gelatin by Varying Hydroxyapatite Concentrations to Fabricate Bioinks for Bone Tissue Engineering

Koutsomarkos N, Platania V, et al.

Polymers

UniVert

Compression Testing

3D Bioprinting & Bioink Materials TestingBone Tissue Engineering & MechanicsCell Laden Hydrogels

2026

Inkjet-Printed Titanium Carbide Nanoparticle-Based Flexible Bidirectional Flow Sensors for Flow-Aware Autonomous Systems

Sengupta D, Birudula S, et al.

ACS Applied Electronic Materials

UniVert

Flexural and Bending Testing

Wearable Bioelectronics

2026

A 3D Bioprinted Spheroid-Laden dECM-Enriched Osteosarcoma Model for Enhanced Drug Testing and Therapeutic Discovery

Domingues M F, Carreira M C, et al.

Advanced Healthcare Materials

UniVert

Compression Testing

3D Bioprinting & Bioink Materials TestingCancer MechanobiologyDrug Screening & Drug Delivery MechanicsHydrogel Mechanical Testing

2026

Contact Sales

Product of Interest: